Safety Cabinet

Short Description:

This specification covers ductless fume hoods for laboratory personnel protection against toxic and hazardous substances. Equipped with dual VOC‑sensor filter saturation alarm, real‑time temperature‑humidity monitoring, high‑efficiency HEPA filtration, IoT touch HMI, duct‑free installation, and lists full parameters for five product models as well as optional configurations....


Product Detail

Product Tags

Feature:

This product is specifically designed to protect laboratory personnel during experimental procedures. It prevents the inhalation of toxic, hazardous, pathogenic, or chemically unidentified substances, efficiently purifies the air within the fume hood and the laboratory, and ensures the safety of the staff.

● Metal components: Primarily constructed from galvanized steel with an epoxy resin electrostatic powder coating; the durable, chemical-resistant, and lead-free finish maintains a high-quality appearance while minimizing the effects of corrosion and moisture. Structural design: The cabinet features an integrated, seamless design at the corners, with rounded contours that enhance the product's overall aesthetic appeal.

● Front and side panels: The front door features a design incorporating either glove ports or fixed access ports to facilitate weighing operations. Constructed primarily from acrylic sheet, the material offers excellent weather resistance and chemical durability; it is resistant to aging, colorless and transparent, and provides uniform light transmission, resulting in a visually pleasing and elegant appearance.

● A real-time environmental monitoring system for temperature and humidity that displays readings and allows for the configuration of alarm parameters, ensuring safe product usage.

● Fan Monitoring: Alarms for fan system malfunctions and adjustable fan speeds (via online control) to ensure the required airflow for handling various chemicals.

● Filter Saturation Alarm System: The unit is equipped with a dual-layer filter and two VOC sensors—one monitoring indoor air quality and the other monitoring filter saturation. A saturation alarm threshold is set for the filter, triggering an alert if the limit is exceeded; the filter requires replacement if the concentration remains above the set value for an extended period. The high-efficiency filtration system features a graded arrangement of media based on particle size and complies with ASTM standards; it effectively targets acidic and organic gases with strong adsorption capabilities and utilizes a high-efficiency HEPA filter for particulates, achieving a filtration efficiency of 99.995% for particles larger than 0.3 μm.

● High-performance fan, 24V operation, stable performance, ultra-quiet, and free from sparks or static electricity.

● Epoxy resin countertops feature superior chemical stability and exceptional corrosion resistance. They offer excellent impact resistance without sustaining damage, withstand high temperatures, and are solid, homogeneous materials throughout. They boast a long service life and do not delaminate, swell, or crack.

● 7 inch large-screen display, IoT-enabled smart HMI, 1024x600 resolution, and a superior visual system;

Advantages:

● No ductwork required; easy installation; no exhaust vented externally; an innovative, eco-friendly solution.

● Optional top-mounted filtration module system available to meet specific experimental requirements.

● Advanced modular filtration technology effectively captures and filters harmful gases, particulates, and dust generated during experiments.

● Eliminates the need for air-conditioning energy consumption, resulting in significant energy savings.

● Can be placed on a tabletop or mounted on a mobile stand; flexible and convenient for use in any complex laboratory setting.

Working Principle:

● Air Intake
Air is drawn directly from the laboratory into the fume hood, creating negative pressure; a stable face velocity forms a natural barrier that isolates the user from the chemicals being handled.

● Comprehensive Filtration System
The fan system draws toxic and hazardous gases upward; after filtration, clean air is returned to the room. The unit's superior containment capabilities ensure that chemical vapors remain inside the hood and do not leak back into the room to cause pollution.

● Laboratory Air Purification
Filters are selected based on specific operations to effectively remove toxic and hazardous gases, purify laboratory air, eliminate residual chemical odors, and enhance the laboratory's cleanliness level.

● Surrounding Air Purification
The fume hood's continuous filtration process helps purify the indoor air.

ModelSpecificationConfigurationOptional
SC 800X600 FHBProfile: 800*620*1245mm
Filter: 370*395*50mm
Pre-filter: 370*395*21mm
Air handling: 230m³/h
Noise: 40-52dBA
Voltage: 110-240V/50-60Hz
Power: 42W
Current: 2A
Operation hole: Trapezoid
Filter: 4 Groups
Pre-filter: 2 PC
Fan: 1 PC
Epoxy resin countertop: 1 PC
Light: LED 1 Group
Display: 7 inch touch screen
Control system: 1 Set
VOC Alert:1 PC
Temperature and Humidity Alarm System: 1 Set
Power cable: 1 PC
Remote monitoring system: 1Set
Filter optional model:
OG: Organic filter
AG: Inorganic filter
AM: Ammonia filter
FO: Formaldehyde filter
HEPA H14: High-efficiency HEPA filter
Stainless steel countertop
Anemometer
Optional alarm:
Ammonia alarm
Formaldehyde alarm
HCL alarm
SC 1000X600 FHBProfile: 1000*620*1245mm
Filter: 370*395*50mm
Pre-filter: 370*395*21mm
Air handling: 230m³/h
Noise: 40-52dBA
Voltage: 110-240V/50-60Hz
Power: 42W
Current: 2A
Operation hole: Trapezoid
Filter: 4 Groups
Pre-filter: 2 PC
Fan: 1 PC
Epoxy resin countertop: 1 PC
Light: LED 1 Group
Display: 7 inch touch screen
Control system: 1 Set
VOC Alert:1 PC
Temperature and Humidity Alarm System: 1 Set
Power cable: 1 PC
Remote monitoring system: 1Set
Filter optional model:
OG: Organic filter
AG: Inorganic filter
AM: Ammonia filter
FO: Formaldehyde filter
HEPA H14: High-efficiency HEPA filter
Stainless steel countertop
Anemometer
Optional alarm:
Ammonia alarm
Formaldehyde alarm
HCL alarm
SC 1200X600 FHBProfile: 1275*620*1245mm
Filter: 370*395*50mm
Pre-filter: 370*395*21mm
Air handling: 690m³/h
Noise: 40-52dBA
Voltage: 110-240V/50-60Hz
Power: 110W
Current: 6A
Operation hole: Trapezoid
Filter: 6 Groups
Pre-filter: 3 PC
Fan: 3 PC
Display: 5 inch touch screen
Control system: 1 Set
VOC Alert:1 PC
Temperature and Humidity Alarm System: 1 Set
Power cable: 1 PC
Remote monitoring system: 1Set
Filter optional model:
OG: Organic filter
AG: Inorganic filter
AM: Ammonia filter
FO: Formaldehyde filter
HEPA H14: High-efficiency HEPA filter
Stainless steel countertop
Anemometer
Optional alarm:
Ammonia alarm
Formaldehyde alarm
HCL alarm
SC 1600X600 FHBProfile: 1600*620*1245mm
Filter: 370*395*50mm
Pre-filter: 370*395*21mm
Air handling: 690m³/h
Noise: 40-52dBA
Voltage: 110-240V/50-60Hz
Power: 110W
Current: 6A
Operation hole: Trapezoid
Filter: 6 Groups
Pre-filter: 3 PC
Fan: 3 PC
Display: 5 inch touch screen
Control system: 1 Set
VOC Alert:1 PC
Temperature and Humidity Alarm System: 1 Set
Power cable: 1 PC
Remote monitoring system: 1Set
Filter optional model:
OG: Organic filter
AG: Inorganic filter
AM: Ammonia filter
FO: Formaldehyde filter
HEPA H14: High-efficiency HEPA filter
Stainless steel countertop
Anemometer
Optional alarm:
Ammonia alarm
Formaldehyde alarm
HCL alarm
SC 1600X700 FHBProfile: 1600*790*1245mm
Filter: 370*395*50mm
Pre-filter: 370*395*21mm
Air handling: 690m³/h
Noise: 40-52dBA
Voltage: 110-240V/50-60Hz
Power: 110W
Current: 6A
Operation hole: Trapezoid
Filter: 6 Groups
Pre-filter: 3 PC
Fan: 3 PC
Display: 5 inch touch screen
Control system: 1 Set
VOC Alert:1 PC
Temperature and Humidity Alarm System: 1 Set
Power cable: 1 PC
Remote monitoring system: 1Set
Filter optional model:
OG: Organic filter
AG: Inorganic filter
AM: Ammonia filter
FO: Formaldehyde filter
HEPA H14: High-efficiency HEPA filter
Stainless steel countertop
Anemometer
Optional alarm:
Ammonia alarm
Formaldehyde alarm
HCL alarm

Leave Your Message


Write your message here and send it to us

Leave Your Message